Device VM-6M

Device VM-6M

The VM-6M device is designed to determine the filtration rate (loss of water) of clay solutions used in drilling oil and gas wells.

 

Instrument performance:

  • – measuring range of filtrate volume, cm³ – ( 0-40 )
  • – actual diameter of the filter, mm – ( 53 )
  • – scale division price, cm³ – ( 1 )
  • – limit of an absolute error of the device, cm ³ – ( ±1,0 )
  • – filtration pressure, MPa – ( 0.1 ±0.01 )
  • – overall dimensions, mm – ( 112 x 275 )
  • – nominal sample volume of the test solution, cm³ – ( 100 )
  • – used oil GOST 20799 – ( I30A )
  • – mass of the device, kg – ( 4 )

 

It is applied according to:

  • – RD 39-00147001-773-2004 “Methods of monitoring parameters of drilling mud”.
  • – GOST R 56946-2016 (ISO 13500: 2008) “Oil and gas industry. Materials of drilling fluids. Technical conditions and tests”.
  • – STO Gazprom 7.3-002-2010 “Regulatory documents for the construction of wells. Drilling fluids. Field tests”.